EPTZ100_ma_en_rev03.doc 37
4.1.10 Alarm
In this menu, the alarm reactions for input contacts are defined.
4.1.11 Initialize
RELAY OFF/ON
It is possible to switch the output relay remotely with
this menu item for test purpose:
ON: output relay switched
OFF: output relay not active (off)
INPUT1...3 PRESET x Assignment of the preset position which is linked to
alarm input.
Select preset position 1~32.
OUTPUT OFF/ON ON: the camera will go to preset [assigned preset
position in lines above] in case of alarm.
In case of alarm, the camera moves to the
defined preset and stays there until manual
PTZ control or any programmed AUTO
RESUME function is carried out
OFF: no reaction in case of active alarm input
RETURN Return to main menu.
POWER ON RESET ON: performs a PTZ initialization similar to power on
OFF: returns to INITIALIZE menu
CAMERA DEFAULT ON: reset of the camera module to factory settings
OFF: returns to INITIALIZE menu
FACTORY DEFAULT ON: reset of the pan/tilt electronics module to factory
settings
OFF: returns to INITIALIZE menu
LENS REFRESH x DAYS OFF,
1...15
Frequent initialization of zoom lens for better stability
and preset precision.
OFF: no frequent initialization
1...15: interval in days for initialization
CAMERA REFRESH x DAYS OFF,
1...15
Frequent initialization of pan/tilt mechanism for better
stability and preset precision.
OFF: no frequent initialization
1...15: interval in days for initialization