EPTZ100_ma_en_rev03.doc 46
7 APPENDIX B: BASIC SETTINGS AT EVERFOCUS DVR
The following settings are required to establish RS-485 communication between DVR and speed dome:
7.1 EDR / EDVR / EDSR SERIES (EXCEPT EDSR100, EDSR100H)
1. CAMERA menu: enter the correct RS-485 ID (address) at the speed dome camera channel.
2. CONTROL menu: under "RS485" :
BAUD RATE: set value identical to camera baud rate
PARITY: NONE
DATA BIT: 8
STOP BIT: 1
PROTOCOL: set protocol identical to speed dome protocol
NOTE: The RS-485 ID in CONTROL menu is not related to speed dome control. This RS-485 ID is used
for controlling DVR by external keyboard only.
7.2 ECOR / PARAGON SERIES
1. CAMERA menu: enter the correct RS-485 ID (address) at the speed dome camera channel.
2. SYSTEM > I/O CONTROL menu:
BAUD RATE: set value identical to camera baud rate
PARITY: NONE
DATA BIT: 8
STOP BIT: 1
PROTOCOL: set protocol identical to speed dome protocol
NOTE: The RS-485 ID in menu I/O CONTROL menu is not related to speed dome control. This RS-485
ID is used for controlling DVR by external keyboard only.