First Alert K5309-5V2 Security Camera User Manual


 
37
(YHQW/RJJLQJ3URFHGXUHV
$ERXW(YHQW/RJJLQJ
The system records various events in a history log, which can be viewed by the master
user using an Alpha Display keypad.
The Event Log holds up to 100 (FA168CPS) or 50 (FA148CP) events.
Events are displayed in chronological order, from most recent to oldest.
When the log is full, the oldest event is replaced by the logging of any new event.
9LHZLQJWKH(YHQW/RJ
1.
+ [#] +
6
+
0
(Master Code)
Alpha Displays:
2. The system displays the most recent event as follows:
event number, type of event (see table of codes below),
zone or user number (depending on type of event)
partition in which event occurred, time and date of
the events occurrence.
3. Pressing [
] displays previous events (back in time).
Pressing [#] displays events forward in time.
4. Exit by pressing any key other than [
] or [#].
8QGHUVWDQGLQJWKH7\SHRI(YHQW'LVSOD\HG
If the event code is preceded by an E (as in the above display), it means that the
event is new and ongoing; if preceded by an R, it means the event has been restored.
See your installer for more detailed information regarding the meanings of these codes
Code - Definition
Code
-
Definition
Code
-
Definition
Code
-
Definition
110 - Fire Alarm
301 - AC Power
380 - Global Trouble, Trouble
Day/Night
441 - Disarm/Arm/ Quick-Arm
STAY/INSTANT
121 - Duress
302 - Low System Battery/Batt
Test Fail
381 - RF Supervision Trouble
442 - Keyswitch Arm/Disarm STAY
122 - Alarm, 24-hour Silent
305 - System Reset (Log only)
382 - Supervsn Aux Wire Zone
570 - Bypass
123 - Alarm, 24-hour Audible
309 - Battery Test Failure
383 - RF Sensor Tamper
601 - Manual Triggered Dialer Test
131 - Alarm, Perimeter
321 - Bell/Siren Trouble
384 - RF Sensor Low-battery
602 - Periodic Test
132 - Alarm, Interior
333 - Trble, Exp. Mod. Supervsn
393 - Clean Me
606 - AAV to Follow
134 - Alarm, Entry/Exit
341 - Trble, ECP Cover Tamper
401 - Disarmed, Armed AWAY,
Armed STAY
607 - Walk Test Entered/Exited
135 - Alarm, Day/Night
344 - RF Receiver Jam
403 - Sched. Arm/Disarm
AWAY
623 - Event Log 80% Full
143 - Alarm, Expansion Module
351 - Telco Line Fault
406 - Cancel by User
625 - Real-Time Clock was Changed
(log only)
145 - ECP Module cover tamper
353 - Long Range Radio Trble
407 - Remote Arm/Disarm
627 - Program Mode Entry (log
only)
146 - Silent Burglary
373 - Fire Loop Trouble
408 - Quick Arm AWAY
628 - Program Mode Exit (log only)
150 - Alarm, 24-Hr Aux/Mon zn
374 - Exit Error Alarm
409 - Keyswitch Arm/Disarm
AWAY
750 -789 - Configurable Zone Type
report codes
162 - Carbon Monoxide