JAI CV-M7+ Security Camera User Manual


 
CV-M4
+
/M4
+
CL, CV-M7
+
/M7
+
CL
- 21 -
6.9. Other Functions.
Functions which can be controlled by either RS-232C or switches, or both.
Gain and set-up.
!! Do not adjust these settings unless you have knowledge to video adjustments!!
The video gain is set to manual. In manual gain mode, either the gain level (GA) or the rear
potentiometer (RP). can adjust the level.
Set-up level. (SU). This setting can adjust the set-up level (or black level).
Vertical Binning (BI). Only vertical binning is possible. It can be selected by the command BI=1,
or by the internal switch SW301-6. (Off 0 normal, ON = V-binnig.)
Binning is only for CV-M4+ and M4+CL.
When binning is active, the horizontal time H is changed from 39.3 µsec. to 43.3 µsec. It will
result in longer exposure times in Edge Pre-Select shutter mode PE.
SYNC/EEN output. (SE). Will select SYNC or EEN signal output on pin #9 on 12-pin connector.
Trigger polarity. (TP). Will invert the trigger-input signal.
LEN/FEN/EEN polarity. (FP). Will invert the LEN, FEN and EEN output signal.
Important notes on using this functions.
Do not attempt to adjust the set-up level without knowledge to it.
Do not attempt to use ASCII commands not shown in “7.5. CV-M4
+
command list.”