JAI CV-M7+ Security Camera User Manual


 
CV-M4
+
/M4
+
CL, CV-M7
+
/M7
+
CL
- 22 -
7. Configuring the Camera
7.1. Mode setting SW1 on rear
seconds
OFF ON
1
2
3
4
5
6
7
8
CONTROL
SHUTTER
SCANNING
< < > >
< > < >
< >
Normal
< >
Local RS232C
Smear-less
<
<
<
<
<
<
<
<
>
<
<
>
<
>
<
<
>
<
<
>
>
<
>
>
1/24
1/50
1/100
1/200
1/400
1/800
1/1500
1/3000
<><><>
<
>
>
<
<
>
<
<
1/5000
1/10,000
<
>
EXT.
TRIGGER
Off
Edge
pre sel.
Pulse
width
Frame
delay
10
9
SMEAR-LESS
< < > >
< > < >
Full
1/2 part.
1/4 part.
1/8 part.
Rear SW
Fig. 25. SW1 on camera rear
7.2. Mode setting SW301 inside
Switch shown with factory settings. SW 6 Binning, for M4+/M4+CL only.
+ High active
- Low active
M4+CL/M7+CL
OFF
ON
1
2
3
4
5
6
7
8
LVDS < > Hirose
Internal SW
TRIGGER sel
TRIGGER pol
LEN/FEN/EEN pol
MULTIPLE EXP.
Off < > On
+ < > -
BINNING
+ < > -
NC
NC
NC
Off < > Ver
M4+/M7+
LEN/FEN/EEN pol
MULTIPLE EXP.
OFF ON
1
2
3
4
5
6
7
8
Off < > Ver
LVDS < > Hirose
Internal SW
Off < > On
+ < > -
BINNING
+ < > -
NC
NC
NC
TRIGGER sel
TRIGGER pol
Shown in factory settings
Fig. 26. Internal Switch
7.3. Internal Switch and Jumper Settings
The jumper JP301 for serial communication is placed on PK8372A. Short = via Camera Link. Open
= RS-232C via the 12 pin Hirose connector.
JP301
SW301
1 8
Fig. 27. Internal switch and jumper setting