JAI CV-M7+ Security Camera User Manual


 
CV-M4
+
/M4
+
CL, CV-M7
+
/M7
+
CL
- 23 -
7.4. RS-232C control
All configuration of the CV-M4
+
camera is done via the RS-232C port. On the 12 pin Hirose
connector, if JP301 is open, or via Camera Link if JP301 is short. The camera can be set up from
a PC running terminal emulator software, or using JAI´s camera control software.
Below is the description of the ASCII based short command protocol.
Communication setting.
TXD
RXD
GND
1 CD
4 DTR
6 DSR
2 RXD
3 TXD
5 GND
7 RTS
8 CTS
9 CI
9 pin
D-con
PC COM
PORT
CAMERA
TXD
RXD
GND
1 CD
4 DTR
6 DSR
2 RXD
3 TXD
5 GND
7 RTS
8 CTS
9 CI
9 pin
D-con
PC COM
PORT
CAMERA
Baud Rate 9600 bps
Data Length 8 bit
Start Bit 1 bit
Stop Bit 1 bit
Parity None
Xon/Xoff Control None
RS 232C cable
Protocol.
Transmit setting to camera:
NN=[Parameter]<CR><LF> (NN is any kind of command. Capital or small letters.)
The camera answers:
COMPLETE<CR><LF>
To have all communication on the emulator screen, start with:
EB=1<CR><LF>
The camera answers:
COMPLETE<CR><LF>
Transmit request command to camera:
NN?<CR><LF> (NN is any kind of command.)
The camera answers:
NN=[Parameter]<CR><LF>
Transmit the following to have the camera actual setting:
ST?<CR><LF>
The camera answers:
A complete list of the current settings
Transmit the following to have a command list:
HP?<CR><LF>
The camera answers:
A list with all commands and possible settings
Invalid parameters send to camera:
SH=99<CR><LF>
The camera answers:
02 Bad Parameters!!<CR><LF>
When the camera is set in “Off Line” (SW1-10 on rear to Local)
NN=[Parameter]<CR><LF>
The camera answers:
03 Offline!!<CR><LF>