JAI CV-M2 Security Camera User Manual


 
CV-M2
- 28 -
7.5. CV-M2 command list
Command Name Format Parameter Remarks
A – General settings and useful commands
EB Echo Back
EB=[Param.]<CR><LF>
0=Echo off 1=Echo on Off at power up
ST Camera Status request ST?<CR><LF>
Actual setting
HP Online Help request HP?<CR><LF>
Command list
VN Firmware version VN?<CR><LF>
3 letter version
ID Camera ID request ID?<CR><LF>
10 Characters
MD Model Name request MD?<CR><LF>
10 Characters
UD User ID
UD=[Param.]<CR><LF>
User text 16 Characters
For user ID data
B – Video Output
OS Output select
OS=[Param.]<CR><LF>
0=single chan.
2=monitor
1=dual chan. 1-2 Camera Link
3 Analog in BNC
BA Output bit allocation
BA=[Param.]<CR><LF>
0=10 bit 1=8 bit Camera Link
MN Monitor mode
MN=[Param.]<CR><LF>
0=EIA (60FPS) 1=CCIR (50FPS) Analog in BNC
C – Timing and shutter related commands
SC Scanning format
SC=[Param.]<CR><LF>
0=full frame
2=1/4 partial
4= progr. p. sc
1=1/2 partial
3=1/8 partial
*)
PS Progr. Par. Scan start
PS=[Param.]<CR><LF>
1-1151 Start line #
PC Progr. Par. Scan hight
PC=[Param.]<CR><LF>
50-1200 Hight line#
TR Trigger mode
TR=[Param.]<CR><LF>
0=normal
2=Restart Cont
4=Burst EPS
1=Edge pre-sel
3=Pulse width
5=PIV
*)
SM Shutter mode
SM=[Param.]<CR><LF>
0=Normal 1=Program. exp
SH Shutter speed
SH=[Param.]<CR><LF>
0=Off (frame)
2=1/120
4=1/500
6=1/2000
8=1/8000
1=1/60
3=1/250
5=1/1000
7=1/4000
9=1/14,000
All10 steps are
valid in normal
trigger mode, EPS
and RCT mode.
PE Programmable expos.
PE=[Param.]<CR><LF>
1-1216 (1.5H to 1216.5H. single chan)
1-1216 (1.5H to 1216.5H. dual channel)
H = 47.9µsec
H = 27.3µsec
BSH1 EPS Burst shutter 1
BSH1=[Param.]<CR><LF>
BSH2 EPS Burst shutter 2
BSH2=[Param.]<CR><LF>
BSH3 EPS Burst shutter 3
BSH3=[Param.]<CR><LF>
BSH4 EPS Burst shutter 4
BSH4=[Param.]<CR><LF>
BSH5 EPS Burst shutter 5
BSH5=[Param.]<CR><LF>
1-1216 (As programmable shutter)
D– Signals and polarity
LS LVAL synchronous accum
LS=[Param.]<CR><LF>
0= syn. accum 1=asyn. accum
TI Trigger Input
TI=[Param.]<CR><LF>
0= CamerLink 1= 12 pin Hirose
TP Trigger polarity
TP=[Param.]<CR><LF>
0= active low 1= active high
SG Sensor Gate control
SG=[Param.]<CR><LF>
0= Off 1= ON Only if TR=0
E – Gain and analogue signals setting
BL Black level master
BL=[Param.]<CR><LF>
0-1023 (0=low, 1023=high)
BLF Black level R fine
BLF=[Param.]<CR><LF>
-512 to 511 (-512=low, 511=high)
GA Gain level master
GA=[Param.]<CR><LF>
0-4095 (0 = low, 4095 =high) Range –4 to 14 dB
GAF Gain level R fine
GAF=[Param.]<CR><LF>
-2048 to 2047 (-2048=low, 2047=high)
KN Knee select
KN=[Param.]<CR><LF>
0=Off 1=ON
KL Knee point master level
KL=[Param.]<CR><LF>
0-1023 (0=low, 1023=high)
KNF Knee point R fine level
KNF=[Param.]<CR><LF>
-512 to 511 (-512=low, 511=high)
GS Gamma select
GS=[Param.]<CR><LF>
0=Off ( =1) 1=ON ( =0.45) Single ch. Only
RP Rear Potentiometer
RP=[Param.]<CR><LF>
0=manual gain 1=rear potm.
AU Auto dual adjust
AU=[Param.]<CR><LF>
0=Off
2=AWA
1=ABA
F – Saving and loading data in EEPROM
LD Load settings from
camera EEPROM
LD=[Param.]<CR><LF>
0=Factory data 1=User 1 area Latest used data
at power up
SA Save settings to camera
EEPROM
SA=[Param.]<CR><LF>
1=User 1 area
Parameter = 0 is
not allowed
EA EEPROM area request EA?<CR><LF>
0=Factory data 1=User 1 area Return the latest
used data area
*) Disconnect the trigger input before changing mode by RS-232C or Camera Link.
!! Do not try to use commands or parameters not shown in this list.