JAI CV-M2 Security Camera User Manual


 
CV-M2
9.2. Specification table
Specifications CV-M2
Scanning system Progressive 1216 lines 17 frames/sec.
Pixel clock 40.00 MHz
Line frequency, single output
dual output
20.88 kHz (1916 pixel clock/line). (H = 47.9 µsec)
36.63 kHz (1092 pixel clock/line). (H = 27.3 µsec)
Frame rate, single output
dual output
17.17 frames/sec. (1216 lines/frame)
30.12 frames/sec. (1216 lines/frame)
CCD sensor 1” progressive scan monochrome IT CCD
Kodak KAI-2000M
Sensing area 11.8 (h) x 8.9 (v) mm
Cell size
7.4 (h) x 7.4 (v) µm
Effective pixels 1600 (h) x 1200 (v)
Pixels in video output
Full
1/2 partial
1/4 partial
1/8 partial
Variable scan
1 channel 2 channel
1600 (h) x 1200 (v) 17.17 FPS 30.12 FPS
1600 (h) x 600 (v) 32.52 FPS 54.67 FPS
1600 (h) x 300 (v) 57.99 FPS 91.58 FPS
1600 (h) x 150 (v) 95.77 FPS 138.75 FPS
1600 (h) x 50 (v) to 1200 (v) <167 FPS <208 FPS
Sensitivity on sensor 1.4 lx (100% video out. Min. gain. 0 dB)
0.2 lx (50% video out. Max. gain. 12 dB)
S/N ratio >50 dB
Video output digital single
digital dual
10 or 8 bit in Camera Link
2 x 10/8 bit in Camera Link
Monitor video output. Analogue
Composite 1.0 Vpp, 75 (50 or 60 FPS. 15.734 kHz)
Iris video output. Analogue
0.7 Vpp, 75 (for iris control)
Gamma 1.0 or 0.45 (Single channel only)
Knee function Slope 100% to 20%. Knee point adjustable
Gain
Gain range
Manual, potentiometer or remote
-3 to +12 dB (0 – 4095)
Synchronization Int. X-tal. Ext. random trigger (LVAL synch. or asynch.)
Inputs TTL
Camera Link
Ext. trigger TTL 4 V ±2 V
Ext. trigger
Outputs TTL
Camera Link
EEN output
Pixel clock output
D0-D9 output
DVAL output
LVAL output
FVAL output
EEN output. (Not specified by Camera Link).
Control interface TXD and RXD via RS 232C
TDX and RDX via Camera Link
Trigger modes
Continuous, Edge pre-select, Pulse width control,
Reset Continuous Trigger, PIV and
EPS Burst (with 5 programmable shutter times)
Read out modes Single or dual digital output. Analogue output.
Partial scan.
Shutter speed (fixed)
Off, 1/60, 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/8000,
1/14,000 second
Pulse width control
1.5 H to . (>72 µsec.) <2 sec. is recommended
Programmable exposure
1.5 H to 1216.5 H (71.9 µsec. to 58.2 msec.) Single channel
1.5 H to 1216.5 H (41 µsec. to 33.2 msec.) Dual channel
Variable scan 50 to 1200 lines
Functions controlled by
RS 232C
Shutter, Trigger, Scanning, Readout,
Trigger input, Video level, Set-up level and Gain
Operating temperature
-5°C to +45°C
Humidity 20 – 80% non-condensing
Storage temp/humidity
-25°C to +60°C/20 – 90% non-condensing
Power
12V DC ± 10%. 6.6 W
Lens mount C-mount
Dimensions 40 x 50 x 120 mm (HxWxD)
Weight 310g
- 31 -