JAI CV-A50 Security Camera User Manual


 
CV-A50 / CV-A60
6.6. Pulse Width Control Mode
The leading edge of the trigger pulse initiates the exposure. The exposure time (accumulation
time) is governed by duration of the trigger pulse.
The resulting video is output as “odd field” for EIA and “even field” for CCIR, and appear 9H
(EIA9 or 10H (CCIR) after the leading edge of WEN (polarity is user selectable).
The exposure time range is 1.5H to 1000H (shortest and longest pulse duration).
To use this mode:
Set function: Trigger mode to “Pulse Width Control” TR=2
Accumulation to “Field” FR=0
Scanning to “Non-interlaced” SC=1
Polarity and other functions
Input: Ext. trigger to pin 5 on 6 pin connector (or pin 11 on 12 pin connector).
Ext HD to pin 6 on 12 pin connector. (If used)
Fig. 19. Pulse width control CCIR.
Fig. 20. Pulse width control EIA.
Important notes on using this mode:-
Do not input external VD signal at Pin No. 7 of the 12-pin Hirose connector, as it may
disturb the external trigger function.
- 13 -