Leica TPS1200 Camcorder User Manual


 
Technical Data TPS1200 173
Accuracy
Object in shade, sky overcast.
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
The display resolution is 0.1 mm.
Characteristics
Standard
measuring
Standard
deviation,
ISO 17123-4
Measure time,
typical [s]
Measure time,
maximum [s]
Reflectorless
1.5 m - 500 m
3 mm + 2 ppm 3 - 6 12
Reflectorless
>500 m
5 mm + 2 ppm 3 - 6 12
Measuring system R100: Special frequency system basis 100 MHz 1.5 m
Measuring system R300: System analyser basis 100 MHz - 150 MHz
Type: Coaxial, visible red laser class 3R
Carrier wave: 670 nm