Leica TPS1200 Camcorder User Manual


 
204TPS1200
Technical Data
There are no special prisms required for ATR or for PS.
Electronic Guide
Light EGL
Automatic
corrections
The following automatic corrections are made:
360° Mini prism,
GRZ121
+30.0 yes not recommended
Reflector tape S,
M, L
+34.4 yes no
Reflectorless +34.4 no no
Type Additive Constant
[mm]
ATR PS
Working range: 5 - 150 m
Positioning accuracy: 5 cm at 100 m
Line of sight error Vertical index error
Tilting axis error Standing axis tilt
Earth curvature Refraction
Circle eccentricity ATR zero point error
Compensator index error