249
n
Flash sync speed • Mechanical shutter: Synchronizes with shutter at
X=
1
/
250 s or slower
• Electronic shutter: Synchronizes with shutter at
X=
1
/
60 s or slower
Release
Mode • Single frame, continuous
• Self-timer, remote, interval timer shooting
Frame advance rate Approx. 6, 10, 20, 30, or 60 fps
Self-timer 2 s, 10 s
Remote control modes Delayed remote (2 s); quick-response remote
Exposure
Metering TTL metering using image sensor
Metering method • Matrix
• Center-weighted: Meters 4.5 mm circle in center of
frame
• Spot: Meters 2 mm circle centered on selected
focus area
Mode t programmed auto with flexible program;
u shutter-priority auto; v aperture-priority auto;
w manual; h scene auto selector
Exposure compensation –3–+3 EV in increments of
1
/
3 EV
Exposure lock Luminosity locked at metered value with A
(AE-L/AF-L) button
ISO sensitivity
(Recommended Exposure
Index)
ISO 160; ISO 200–12800 in steps of 1 EV; 6400
(NR); 12800 (NR); auto ISO sensitivity control (ISO
160–6400, 160–3200, 160–800) available (user
controlled in t, u, v, and w modes)
Active D-Lighting On, off