Panasonic AW-E750 Security Camera User Manual


 
-20-
CONNECTION OF A REMOTE CONTROL BOX (RCB)
The RCB (WV-CB700A) and the camera must be con-
nected with the optional RCB cable AW-CA50T10.
1. Turn RCB power off before connecting cables.
2. Connect the 50-pin connector of the RCB cable to
I/F REMOTE connector of the camera. The 10-pin
connector must be connected to the RCB.
3. Turn RCB power on and the camera can be con-
trolled remotely by the RCB.
Notes:
The monitor output signals of the RCB attenuate
and deteriorate with cable length. It is recommend-
ed that the signals from the monitor output be used
for monitoring purposes only.
No gen-lock signal is available from the RCB.
If a longer distance (more than 3 m) is desired
between the camera and the RCB, use the following
optional cable.
AW-CA50B10 and WV-CA10B02 (2 m)
WV-CA10B25 (25 m)
WV-CA10B50 (50 m)