8. Digital Gain Up Setting
[Digital Gain Up: 0dB, 6dB, 12dB, 18dB, 24dB, 30dB]
This can be set when a setting other than Auto has
been selected as the gain setting (6-7).
0 dB: Under normal circumstances, this setting is
used.
6 dB to 30 dB: Use this setting while shooting dark
scenes if it is not possible to achieve a satisfacto-
ry video output even when the lens diaphragm is
opened and Night Eye is selected as the gain
setting (6-7).
9. AGC Maximum Gain Setting
[AGC Max Gain: 6dB, 12dB, 18dB, 24dB, N/Eye L,
N/Eye H] (AW-E750, AW-E655, AW-E650)
[AGC Max Gain: 6dB, 12dB, 18dB, 24dB, N/Eye]
(AW-E350)
This is used to set the maximum gain up when Auto
has been selected as the gain setting (6-7).
10. CCD Storage Time setting
[Charge Time: Auto, OFF, 1/30s, 1/15s, 1/8s, 1/4s,
1/2s, 1s, 2s]
This is used to set the CCD storage time.
OFF: Under normal circumstances, this setting is
used.
Auto: ALC is performed followed by AGC and then
by the data storage, and the camera automatical-
ly adjusts the light quantity.
If the electronic shutter mode setting (6-5) is set
to ELC, ELC is performed followed by ALC,
AGC and then by the data storage in this order,
and the light quantity is automatically adjusted.
The electronic shutter mode setting (6-5) cannot
be changed at this time.
1/30s to 2s: Use this setting if it is not possible to
achieve a satisfactory video output even when
the gain up setting is used.
The electronic shutter go OFF at this time, the
electronic shutter mode setting (6-5) and elec-
tronic shutter step/synchro scan setting (6-6)
cannot be changed.
If the CCD read out (mode) setting (;-9) has been
set to Frame1 or Frame2, 1/15s to 2s is selected
as the storage time setting, and the sensitivity is set
to about one-half of that obtained with when the
CCD read-out (mode) setting (;-9) has been set to
Field.