Panasonic AW-E750 Security Camera User Manual


 
-46-
7. Gain Setting
[Gain: Auto, 0 dB to 30 dB, N/Eye L, N/Eye H]
(models AW-E750, AW-E655, AW-E650)
[Gain: Auto 0 dB to 30 dB, N/Eye]
(model AW-E350)
When Auto has been selected as the CCD storage
time setting (6-10), the setting is kept to Auto
regardless of the gain setting selected here.
Auto: The light quantity is adjusted automatically.
0 dB: Under normal circumstances, this setting is
used.
1 dB to 30 dB: Use this setting while shooting dark
scenes if it is not possible to achieve a satisfacto-
ry video output even when the lens diaphragm is
opened.
AW-E750, AW-E655, AW-E650
N/Eye L (Night Eye L) : Use this setting if it is not
possible to achieve a satisfactory video output
even at 30 dB.
N/Eye H (Night Eye H) : Use this setting if it is not
possible to achieve a satisfactory video output
even at the Night Eye L setting.
AW-E350
N/Eye (Night Eye) : Use this setting if it is not possi-
ble to achieve a satisfactory video output even at
30 dB.
Only 0 dB, 9 dB, or 18 dB, AGC LOW, AGC HIGH
can be selected in case of using the RCU (RCB).
If the lens iris switch is at MANUAL, when operat-
ing the camera alone or when the iris switch on the
RCU (RCB, Hybrid control panel) is at AUTO, AGC
may not function.
AGC HIGH when the AGC selection switch on the
hybrid control panel is at AGC.
0 dB when the manual gain switch on the hybrid
control panel is at LOW, 9 dB when it is at MID, or
18 dB when it is at HIGH.
Notes
Hybrid Control Panel
AGC Switch
Manual GAIN Switch