Panasonic AW-E750 Security Camera User Manual


 
-45-
5. Electronic Shutter Mode Setting
[Shutter Mode: Step, ELC, S/Scan]
Step: Electronic shutter operates at the speed
selected by the Electronic Shutter Step/Synchro
Scan Setting (6-6).
ELC: Electronic shutter is controlled to automatically
adjust the luminance.
S/Scan (Synchro Scan): Electronic shutter operates
at the speed selected in Electronic Shutter
Step/Synchro Scan Setting (6-6).
6. Electronic Shutter Step/Synchro Scan Setting
[Step/Synchro: OFF, 1/100 to 1/10 000 (step),
60.34Hz to 15.75kHz (Synchro Scan)]
This can be set when Step or Synchro Scan has
been selected as the electronic shutter mode setting
(6-5).
When Step has been selected as the electronic
shutter mode setting (6-5):
OFF: The electronic shutter is set to OFF.
1/100, 1/250, 1/500, 1/1 000, 1/2 000, 1/4 000, 1/10000:
The electronic shutter operates at the shutter
speed selected.
When Synchro Scan has been selected as the
electronic shutter mode setting (6-5):
When the screen of a work station, etc. is to be
shot, the noise on the horizontal bars can be
reduced by proceeding with the synchro-scan
adjustment.
Refer to the table below for the light quantity set-
tings to be used in each shutter mode and during
synchro scanning.
If Frame 1 is selected in CCD Read Out Mode
Setting (;-9), Electronic Shutter Mode Setting
cannot be added.
Note
Shutter Speed
OFF
1/100
1/250
1/500
1/1 000
1/2 000
1/4 000
1/10 000
Synchro-scan
-
100.3 Hz
250.0 Hz
492.2 Hz
984.4 Hz
1.969 kHz
3.938 kHz
7.875 kHz
Required luminance ratio
1
2
4
8
16
32
64
160
In case of using the RCU (RCB), none of the
shutter speeds 1/250, 1/2 000, 1/4 000, and
1/10 000 can be selected.
In case of using the hybrid control panel, only
OFF, 1/100, or ELC can be selected.
If the lens iris switch is at M (Manual) when
operating the camera alone or when the iris
switch on the RCU (RCB) is at AUTO, ELC
may not function. Set the lens iris switch to A
(Auto).
Flickering may increase at ELC under fluorescent
lights.
Notes