Philips Orion/2 Security Camera User Manual


 
Orion/2 Outdoor
31
ALARM PIN
The dome provides 8 alarm inputs and 2 outputs (1× N.O. and 1× N.C.). Select
an alarm connector which you want to set its alarm-related parameters with this
item, and then set its alarm-related parameters in Alarm Setting menu. For alarm
pin definitions, please refer to section 2.6 Alarm Pin Definition
or installation
guide.
ALARM SWITCH
The item is used to enable or disable the selected alarm pin function. Use the
left/right direction keys on the control keyboard to change the setting.
ALARM TYPE
There are two kinds of alarm types: Normal Open and Normal Close, which are
illustrated as below. Select an alarm type that corresponds with the alarm
application.
ALARM ACTION
Select one of these modes that choose a kind of actions that should be executed
when an alarm is triggered. The alarm actions can be set to execute the preset
position, sequence, auto-pan or cruise function. Use the right direction key of the
control keyboard to change the setting, and the bellowing items will change in
cooperating with your selection.
PRESET
Select a preset point where the dome should go when an alarm pin is triggered.
The Preset points can be set by a control keyboard.
ALARM SETTING
ALARM PIN 1
ALARM SWITCH OFF
ALARM TYPE N.C.
ALARM ACTION PRESE
T
PRESET POINT 001
DWELL TIME ALWAY
EXIT YES