Philips Orion/2 Security Camera User Manual


 
Orion/2 Outdoor
32
SEQUENCE
Select a sequence line that the dome camera should execute when alarm pin is
triggered. The Sequence line should be defined prior in SEQUENCE setup
menu.
AUTOPAN
Select an auto-pan line that the dome camera should execute when alarm pin is
triggered. The Auto-pan line can be defined in setup AUTOPAN menu.
CRUISE
Select a cruise line that the dome camera should execute when alarm pin is
triggered. The Cruise line can be defined in CRUISE setup menu.
DWELL TIME
The DWELL TIME is the duration of executing ALARM ACTION: Preset or
Sequence. When alarm takes place, the dome will go to the preset position or
execute sequence function and stay at each sequence point for a period of time
(1~127 seconds). If select <Always>, the dome will go to the preset position and
stay there until alarm condition is released or users rotate the dome.
NOTE: The DWELL TIME is only accessible when selecting ALARM
ACTION: Preset or Sequence.
EXIT
Exit the ALARM SETTING menu.
3.3.13 HOME SETTING
Users are able to set an operation mode to ensure constant monitoring; if the dome
idles for a period of time, the pre-set function will be activated automatically, this is
the HOME function. HOME function allows constant and accurate monitoring, to
avoid the dome stops or missing events.
HOME FUNCTION
The item is used to enable or disable the HOME function. Use the left/right
direction keys of the control keyboard to change the setting.
HOME SETTING
HOME FUNCTION OFF
SELECT MODE PRESE
T
PRESET POINT 001
RETURN TIME 001
GO ENTER