Sanyo VCC-MD400 Security Camera User Manual


 
− 16 −
Message
Backlight BLC OFF A0 06 00 CS FF Backlight compensation OFF
Multi BLC ON A0 06 01 CS FF Backlight compensation multifractionated evaluative metering mode (Backlight compensates after
measuring the light of the entire screen.)
Multi BLC Weight - A0 06 04 00 CS FF Sensitivity settings during Multi BLC
BLC is easier to determine with a larger value (Initial value: 7)
Multi BLC Weight + A0 06 04 01 CS FF
Multi BLC Weight Preset A0 06 05 CS FF Returns sensitivity during Multi BLC to factory defaults (Initial value: 7)
Multi BLC Weight Direct A0 06 06 0p CS FF p: Direct sensitivity settings 0-15 during Multi BLC (Initial value: 7)
Multi BLC Bright - A0 06 07 00 CS FF Brightness settings during Multi BLC
Larger value increases brightness when determining BLC (Initial value: 7)
Multi BLC Bright + A0 06 07 01 CS FF
Multi BLC Bright Preset A0 06 08 CS FF Returns brightness settings during Multi BLC to factory defaults (Initial value: 7)
Multi BLC Bright Direct A0 06 09 0p CS FF p: Direct brightness settings 0-15 during Multi BLC (Initial value: 7)
Center BLC ON A0 06 0B CS FF BLC center-weighted metering mode (Backlight compensates after measuring the light mainly in the
center.)
Center BLC Weight Preset A0 06 0F CS FF Returns sensitivity settings during Center BLC to factory defaults (Each initial value: 0)
Center BLC Weight Direct A0 06 10 0p 0q 0r 0s CS FF Sensitivity settings during Center BLC
p: Top(0-7) q: Bottom(0-7) r: Left(0-7) s: Right(0-7) (Each initial value: 0)
Center BLC Area Preset A0 06 12 CS FF
Returns center area settings during Center BLC to factory defaults
(Each initial value: 0)
Center BLC Area Direct A0 06 13 0p 0q 0r 0s CS FF Center area settings during Center BLC
p: x-position(0-7) q: y-position(0-5) r: x-size(0-7) s: y-size(0-5)
(Initial value: x-position: 2 y-position: 1 x-size: 3 y-size: 3)
*When x-size:0 y-size:0, it becomes 1 area.
Mask BLC ON A0 06 15 CS FF BLC mask mode
Mask BLC Area Preset A0 06 19 CS FF Return mask area settings during Mask BLC to factory defaults
Mask BLC Area Direct A0 06 1D 0p 0q 0r 0s 0t 0u Mask area settings during Mask BLC (Note 1)
0v 0w 0x 0y 0z 0n CS FF
BLC ON A0 06 33 CS FF Returns to the mode before BLC OFF only when BLC OFF
Shutter
Speed
Shutter Speed + A0 07 0B CS FF Increases shutter speed by one notch
Shutter Speed - A0 07 0C CS FF Decreases shutter speed by one notch
Shutter Speed Set long A0 07 0E 0p CS FF Shutter Speed Mode Settings
0: Prolonged exposure shutter mode, 1: Normal mode, 3: High speed shutter mode
Shutter Speed OFF A0 07 0F CS FF Same as Shutter Speed Set OFF
Shutter Long Direct A0 07 11 0p CS FF Shutter speed settings during prolonged exposure shutter mode
(0: x1, 1: x2, 2: x4, 3: x8, 4: x16, 5: x32)
Shutter Short Direct A0 07 12 0p CS FF Shutter speed settings during high speed shutter mode
(0: 1/60 (50), 1:1/100 (120), 2: 1/250, 3: 1/500, 4: 1/1000, 5: 1/2000, 6: 1/4000, 7: 1/10000)
Sense Up + A0 07 1A CS FF Increase electronic sensitivity settings
Sense Up - A0 07 1B CS FF
Sense Up Direct A0 07 1D 0p CS FF p: Direct increased electronic sensitivity settings
(0: OFF, 1: x2, 2: x4, 3: x8, 4: x16, 5: x32)
ELS OFF A0 07 28 CS FF Sets shutter speed to 1x (1/60) after saving
ELS ON A0 07 29 CS FF Returns to electronic shutter speed saved by ELS OFF
Motion
Detector
Motion Detector OFF A0 08 00 CS FF
Motion sensor ON/OFF
Motion Detector ON A0 08 01 CS FF
Motion Size Preset A0 08 05 CS FF Returns detected motion size settings to factory defaults (Initial value: V-Size: 1, H-Size: 1)
Motion Size Direct A0 08 06 0p 0q CS FF Detected motion size settings p: V-Size (1-6) q: H-Size (1-8) (Initial value: V-Size: 1, H-Size: 1)
Alarm Sign OFF A0 08 08 CS FF
Display ON/OFF during alarm input
Alarm Sign ON A0 08 09 CS FF
Masking OFF A0 08 0A CS FF
Mask area settings for motion detection ON/OFF
Masking ON A0 08 0B CS FF
Mask Area Preset A0 08 0F CS FF Returns mask area for motion detection to factory defaults
Mask Area Direct A0 08 13 0p 0q 0r 0s 0t 0u Mask area settings for motion detection (Note 1)
0v 0w 0x 0y 0z 0n CS FF
Sensitivity Move + A0 08 15 CS FF
Motion detection sensitivity settings (Initial value: 5)
Sensitivity Move - A0 08 16 CS FF
Sensitivity Move Preset A0 08 19 CS FF Returns motion detection sensitivity settings to factory defaults (Initial value: 5)
Sensitivity Move Direct A0 08 1D 0p CS FF p: Direct motion detection sensitivity settings 1-10 (Initial value: 5)
Sensitivity Y-Level + A0 08 1F CS FF
Minimum brightness settings for motion detection (Initial value: 5)
Sensitivity Y-Level - A0 08 20 CS FF
Sensitivity Y-Level Peset A0 08 23 CS FF Returns minimum brightness settings for motion detection to factory default (Initial value: 5)
Sensitivity Y-Level Direct A0 08 27 0p CS FF p: Direct minimum brightness settings for motion detection 1-10 (Initial value: 5)
Sensitivity Y-Differ + A0 08 29 CS FF
Brightness variation settings for undetected motion (Initial value: 5)
Sensitivity Y-Differ - A0 08 2A CS FF
Sensitivity Y-Differ Preset A0 08 2D CS FF Returns brightness variation settings for undetected motion to factory defaults (Initial value: 5)
Sensitivity Y-Differ Direct A0 08 31 0p CS FF p: Direct brightness variation settings for undetected motion 1-10 (Initial value: 5)
Sensitivity Duration + A0 08 33 CS FF
Continuous movement time for motion detection (Initial value: 1)
Sensitivity Duration - A0 08 34 CS FF
Sensitivity Duration Preset A0 08 37 CS FF Returns continuous movement time for motion detection to factory defaults (Initial value: 1)
Sensitivity Duration Direct A0 08 3B 0p CS FF p: Direct continuous movement time for motion detection 1-60 (Initial value: 1)
Motion Zoom A0 08 3D 0p CS FF p: Zoom magnification during motion detection
(0: OFF, 1: x1.4, 2: x2, 3: x2.8, 4: x4, 5: x6)
Motion Interval A0 08 42 0p CS FF p: Interval time until the start of next detection during motion detection
(0: 5s, 1: 10s, 2: 15s, 3: 20s, 4: 30s, 5: 1m, 6: 2m, 7: 3m, 8: 4m, 9: 5m)
Sync Sync INT A0 09 00 CS FF Internal synchronization mode
Sync L-L A0 09 01 CS FF Power supply synchronization mode
L-L Phase + A0 09 0B CS FF
Synchronous phase settings for power source synchronization
L-L Phase - A0 09 0C CS FF
L-L Phase Preset A0 09 0F CS FF Returns synchronous phase settings for power source synchronization to factory defaults
(Initial value: 0)
L-L Phase Direct A0 09 13 0p 0q 0r CS FF pqr: Synchronous phase settings for power source synchronization
Direct 0-524 (NTSC) / 0-624 (PAL) (Each initial value: 0)
*1: Only MD400 CS: Checksum
*2: Only MD300 FF: Terminator
Communications Protocol
Model: VCC-MD400/300