Speco Technologies DVR-4TN Camcorder User Manual


 
User’s Manual
DVR-4TN/8TN/16TN/16TS/16TT Series
SPECO TECHNOLOGIES 01/06
46
Users are allowed to change the RS-485 settings of the
DVR-4TN/8TN/16TN/16TS/16TT series unit. Select <System Setup> in the
Main menu, then select <RS485 Setup> from the System Setup menu and
press ENTER. The following menu is displayed.
RS485 Setup
1 Unit ID
2 Baud Rate
3 Bits
4 Stop
5 Parity
224
9600
8
1
None
The ID number must match the ID address set by the dome. The Unit ID is
within the range of 1 to 255. The default ID is 224. Note that no two devices on
the same bus should be given the same ID address, or a conflict may occur.
The default DVR-4TN/ DVR-8TN/ DVR-16TN series RS-485 settings are 9600
Baud, 8 Data Bits, 1 Stop Bit and No Parity.
NOTE: The settings become effective after saving the changes and
exiting from the menu.
4.6.4 Dome Controlling Key
The function keys used in Dome Control are illustrated below.
Set / Go Preset
This key is used to enter the Dome Preset menu to enable the set up of a
specific position as a preset and to go to the predetermined preset positions
for viewing.