Bosch Appliances NBN-921 Security Camera User Manual


 
58 en | Advanced Mode DinionHD 720p IP Camera
AR18-10-B013 | v1.52 | 2011.06 Installation and Operation Manual Bosch Security Systems
Actual shutter
Displays the actual shutter value from the camera to help
compare lighting levels and optimum shutter speed during set-
up.
Sensitivity up
In AES mode, selects the factor by which the sensitivity of the
camera is increased (OFF, 2x, 3x, etc. to a maximum of 10x).
Note:
If Sensitivity up is active, some noise or spots may appear in
the picture. This is normal camera behavior. Sensitivity up may
cause some motion blur on moving objects.
Gain
AGC - the camera automatically sets the gain to the lowest
possible value needed to maintain a good picture.
Fixed - sets Fixed gain value.
Maximum gain / Fixed gain
Selects the maximum value the gain can have during AGC
operation (0 to 30 dB).
Selects the gain setting for Fixed gain operation (0 is no gain).
Actual gain
Displays the actual AGC value from the camera to help compare
gain level with lighting levels and picture performance.