DinionHD 720p IP Camera Advanced Mode | en 97
Bosch Security Systems Installation and Operation Manual AR18-10-B013 | v1.52 | 2011.06
Select
Select External device or Motion+/IVA to trigger the relay.
Relay name
The relay can be assigned a name here. The name is shown on
the button next to Trigger relay. The LIVEPAGE can also be
configured to display the name next to the relay icon. (Do not
use any special characters, for example &.)
Trigger relay
Click the button to switch the relay manually (for example, for
testing purposes or to operate a door opener).
9.7.3 COM1
Configure the data connector for the camera.
Serial port function
Select a controllable unit from the list. If you wish to use the
serial port to transmit transparent data, select Transparent.
Select Terminal if you wish to operate the unit from a terminal.
After selecting a unit, the remaining parameters in the window
are set automatically and should not be changed.
Camera ID
If necessary, enter the ID of the peripheral you wish to control
(for example a dome camera or pan/tilt head).
Baud rate
Select the value for the transmission rate in bps.
Data bits
The number of data bits per character cannot be changed.
Stop bits
Select the number of stop bits per character.
Parity check
Select the type of parity check.
Interface mode
Select the desired protocol for the serial interface.