Bosch Appliances X20 Security Camera User Manual


 
VideoJet X20 Configuration Using a Web Browser | en 57
Bosch Security Systems Installation and Operating Manual V3.5 | 2007.12
5.19.1 Standard profile
From this field, you can select the encoder profile to be used for continuous recording (see
Section 5.11 Encoder Profile, page 38).
5.19.2 Encoder
Here you can select the data stream to be used for the recording.
5.19.3 Alarm track recording
X Click the checkbox to activate alarm track recording. The pre-alarm time is automatically
displayed for information.
5.19.4 Post-alarm time
You can select the required post-alarm time from the list field.
5.19.5 Post-alarm profile
You can select the encoder profile to be used for recording during the post-alarm time (see
Section 5.11 Encoder Profile, page 38).
The Standard profile option adopts the selection for continuous recordings at the top of the
page.
5.19.6 Alarm input / Motion alarm / Video loss alarm
Here you can select the alarm sensor that is to trigger a recording. You can also use the
motion and video alarm for a camera to trigger the alarm recording by another camera.
i
NOTICE!
The recording profile can deviate from the standard setting Active profile for the video input
set and is only used during an active recording.
i
NOTICE!
This parameter is active only if alarm tracks have been configured for the camera input
concerned, i.e. the corresponding partition (see Section 5.18.8 Number of alarm tracks,
page 55).
i
NOTICE!
The motion alarms are configured and activated for each camera on the VCA page (see
Section 5.23 VCA, page 64).
The alarm inputs are configured and activated on the Alarm Sources page (see
Section 5.21 Alarm Sources, page 60).
The numbering of the checkboxes for the alarm inputs corresponds to the labeling of the
alarm inputs on the VideoJet X20. The motion and video alarm corresponds to the labeling on
the video inputs.