Bosch Appliances X20 Security Camera User Manual


 
74 en | Configuration Using a Web Browser VideoJet X20
V3.5 | 2007.12 Installation and Operating Manual Bosch Security Systems
5.27 COM1
You can configure the serial interface parameters (orange terminal block) to meet your
requirements.
5.27.1 Serial port function
Select a controllable unit from the list. If you wish to use the serial port to transmit
transparent data, select Transparent. Select Terminal if you wish to operate the unit from a
terminal.
i
NOTICE!
If the VideoJet X20 is working in multicast mode (see Section 5.29 Multicasting, page 80), the
first remote location to establish a video connection to the unit is also assigned the
transparent data connection. However, after about 15 seconds of inactivity the data
connection is automatically terminated and another remote location can exchange
transparent data with the unit.
i
NOTICE!
After selecting a unit, the remaining parameters in the window are set automatically and
should not be changed.