Bosch Appliances X20 Security Camera User Manual


 
68 en | Configuration Using a Web Browser VideoJet X20
V3.5 | 2007.12 Installation and Operating Manual Bosch Security Systems
5.23.16 Select area
You can select the image areas in the reference image that are to be monitored. The video
image is subdivided into 858 square fields. Each of these fields can be activated or
deactivated individually.
1. Click Select area to configure the sensor fields. A new window will open.
2. If necessary, click Clear all first to clear the current selection (fields marked yellow).
3. Left-click the fields to be activated. Activated fields are marked yellow.
4. If necessary, click Select all to select the entire video frame for monitoring.
5. Right-click any fields you wish to deactivate.
6. Click OK to save the configuration.
7. Click the close button X in the window title bar to close the window without saving the
changes.
i
NOTICE!
Select only those areas for reference monitoring in which no movement takes place and that
are always evenly lit, as false alarms could otherwise be triggered.