EverFocus EPHD04+ Security Camera User Manual


 
EPHD04+ HDcctv DVR
60
Timeout: Select this option and then set up the Timeout Duration in the field below, the
alarm output will last for the setup duration time (1 ~ 150 seconds).
Permanent: Alarm will remain active until the user presses the “Enter” key on the IR
Remote Control or resets the alarm remotely.
Transparent: Alarm output remains as long as the alarm input is active.
Trans + Timeout: Alarm output continues until event ends, then continues for the setup
duration time (1 ~ 150 seconds).
Timeout Duration: This function only appears when you select Timeout or Trans + Timeout
options in the Output Type drop-down list. Select a duration time for the motion event. The
alarm output will last for the setup duration time between 1 and 150 seconds.
Main Monitor: Select Full Screen to force the camera which detects motion to display full
screen on the Main Monitor. The full screen camera view will last according to the Output
Type selected in the field above.
Call Monitor: Select Full Screen to force the camera which detects motion to display full
screen on the Call Monitor. The full screen camera view will last according to the Output Type
selected in the field above.
Edit Motion Grid: Press the button to bring up the Motion Setting menu. To edit the motion
grids, please refer to the instructions later in this section.
Apply To: Click the button to apply the same settings to the desired cameras.
To Edit the Motion Grids:
1. Click the Edit Motion Grid button, the Motion Setting menu appears.
Figure 6-5
2. Click on the image and the grid will be displayed.