JVC RM-HP250DE Camera Accessories User Manual


 
30
Operation of Connected Camera
When RM-HP250 is connected to a camera, all features that are available on RM-HP250 can only be
controlled by RM-HP250, and control of these features using the camera is disabled.
Switches on the camera that are disabled, as well as disabled menu items are as follows.
General
Standard connection of RM-HP250 (Connection of 2 units)
GAIN
SHUTTER(1
WHT.BAL
FULL AUTO(2
User 1, 2 and 3 with the following features assigned
BARS
B.STRETCH1-5
B.COMPRESS1-5
AE LEVEL +
AE LEVEL –
(1 SHUTTER will also be disabled if the setting is “VARIABLE” or below “1/30” (When Frame rate is 60/24) or “1/25” (When
Frame rate is 50).
(2 Setting is configured from RM-HP250 regardless of the status of the FULL AUTO switch.
NOTE
Menu items that are disabled
Menu Display on
Menu Page Function
GY-HD250/GY-HD251
CAMERA OPERATION AE LEVEL REMOTE
SMOOTH TRANS REMOTE
BARS REMOTE
CAMERA PROCESS [1/2] MASTER BACK REMOTE
DETAIL REMOTE
V/H BALANCE REMOTE
H. FREQUENCY REMOTE
SKIN DETECT REMOTE
CAMERA PROCESS [2/2] BLACK REMOTE
KNEE REMOTE
LEVEL REMOTE
DNR REMOTE
ADVANCED PROCESS CINEMA [OFF](3
GAMMA [STANDARD](4
[CINEMA](4
[FILMOUT](4
LEVEL REMOTE
WHITE BALANCE WHITE PAINT R REMOTE
WHITE PAINT B REMOTE
GENLOCK SD H PHASE REMOTE
HD H PHASE REMOTE
SC COARSE REMOTE
SC FINE REMOTE
NOTE
(3 CINEMA is forcibly set to “OFF”. To adjust MATRIX, make ues of the menu on the camera.
(4 GAMMA is fixed at the menu setting value of the camera before connecting to the remote control. However, when the menu
setting value is OFF, GAMMA will be forcibly set to STANDARD.
NOTENOTE