JVC VN-C655U Digital Camera User Manual


 
19
This terminal is for connecting with an alarm annunciator such as an indicator, a
lamp or a buzzer.
8. Alarm Output Terminal
Output Requirements
Equivalent to NPN open collector output
(The output logic is set with [V.Networks Setup
Tool.])
Allowed applied voltage: DC 12 V max.
Allowed input current: 50 mA
Momentary output: 1 to 5000 ms
(The duration is set with [V.Networks Setup
Tool.])
VN-C655
Annunciator
Connection
Example
Output
terminal
IN
R
DC 12 V
(Alarm output equivalent circuit)
Grounding
terminal
GND
Caution
Connect the VN-C655 grounding terminal
to the one of the annunciator.