Kamera Werk Dresden CMOS Digital Camera User Manual


 
Version 1.08 (04/07)Manual: CMOS Industrial Camera LOGLUX
i5

Page 16 of 46KAMERA WERK DRESDEN GmbH
The 'Profile globals' menu
The menu is used for renaming the selected camera profile, initializing the selected profile with one of
the factory settings, or copying all parameters of a profile to the selected profile.
The user can change the name of the selected
profile in the 'Profile Name' input field. All
upper-case and lower-case letters and
numerals as well as the separating character
'_' are available for the purpose. The new
name will be valid, and the respective entry in
the tree structure updated, immediately upon
leaving the input field. The profile name may
have up to 32 digit positions
The 'Init profile' option allows the user to
initialize the selected profile with one of the
factory-set profiles. It should be noted here that
all settings of the chosen profile are
overwritten!
This option is ideal for user-specific
optimization purposes as suitable profile
parameters have already been pre-set for up to
four applications.
In 'Load profile', the user can load the selected
profile with all parameters of another profile. It
should be noted that settings of the selected
profile get lost!
This option is ideal for copying profiles of
identical contents.
Both options are activated by clicking button
'Init now' and 'Load now', respectively.
In panel 'Profile backup', the user can store the
active program in a backup file (.INI file) or
restore it from a backup file (.INI file).
Optionally, a backup file may also be stored in
a script file which can be called up in the built-
in terminal program by the restore function.
Figure 12 : The 'Profile globals' menu