Kamera Werk Dresden CMOS Digital Camera User Manual


 
Version 1.08 (04/07)Manual: CMOS Industrial Camera LOGLUX
i5

Page 24 of 46KAMERA WERK DRESDEN GmbH
The 'Look-up Table x' menu
This menu is used for loading one of the three user-specific look-up tables in the camera to the host
system, and loading, or saving, user-specific look-up tables (LUT) from the host system (PC/IPC) to
the camera.
The user can enter the desired LUT name in
the 'Name' field. All upper-case and lower-case
letters and numerals as well as the separating
character '_' are available for the purpose.
The buttons under 'Actions' allow the user to
choose from the following LUT functions:
Read The selected LUT is transferred
from the camera to the host system (PC/IPC),
and the function values are displayed under
'Lookup table contents'. By clicking button
'Save', the transferred LUT can be saved as a
text file in the host system (PC/IPC).
Load A LUT (text file) in the host system
is selected to be transferred to the camera.
When the button is pressed, the standard
Windows
dialog 'Load LUT from ...' is opened,
and the user can choose the desired file (in the
.TXT format). Clicking the 'Write' button
transfers the selected LUT to the camera.
Save / Write A LUT transferred from the
camera is saved as a text file in the host
system LUT ('Save'), or a LUT is transferred
from the host system (PC/IPC) to the camera
('Write'). When clicking 'Save', the standard
Windows
dialog 'Save LUT to ...' is opened,
and the user can name the desired .TXT file.
Note that the inscription and function of the
'Save/Write' button will not be visible and
active, respectively, until the 'Read' or 'Load'
button is pressed.
Figure 20 : The 'Look-up table x' menu