Kamera Werk Dresden CMOS Digital Camera User Manual


 
Manual: CMOS Industrial Camera LOGLUX
i5Version 1.08 (04/07)

KAMERA WERK DRESDEN GmbHPage 33 of 46
PROFILE_TRGRATEThe register specifies the rate, or frequency, of framegrabbing (in Hz, or
snapshots per second) after triggering for a sequence of snapshots or a
continuous "snapshot" (video). Where the readout speed of an image is
sufficiently low, the actual image rate corresponds to the framegrabbing rate,
with the following condition having to be satisfied:
PIXELCLK / (WIDTH * HEIGHT) < TRGRATE
Otherwise, the framegrabbing rate is limited in dependence of the readout
speed to the maximum possible framegrabbing rate value.
Example: w $108 #30;Image rate is 30 Hz
PROFILE_SMODEThis register specifies the framegrabbing mode of the camera triggering
system. A single snapshot, sequence of snapshots or video can be generated
upon triggering.
Example: w $10A #1;Trigger for single snapshot
PROFILE_TMMODERegister PROFILE_TMMODE activates one of the available LUT functions
serving the link-up with the incoming image data:
The image data are subtracted from the constant 1024 which results in an
inversion of the image data.
The image data are shifted to the right bit by bit (by n bits). Zeros are
inserted at the most significant bits (MSB), the lowest significant bits (LSB)
get lost.
The image data are subtracted from the constant 1024 which results in an
inversion of the image data. Simultaneously, the image data are shifted to
the right bit by bit (by n bits). Zeros are inserted at the most significant bits
(MSB), the lowest significant bits (LSB) get lost.
The image data are shifted to the left bit by bit (by n bits). Zeros are
inserted at the lowest significant bits (MSB), the most significant bits (LSB)
get lost.
The image data are subtracted from the constant 1024 which results in an
inversion of the image data. Simultaneously, the image data are shifted to
the left bit by bit (by n bits). Zeros are inserted at the lowest significant bits
(MSB), the most significant bits (LSB) get lost.
A test image is displayed. The region of interest is subdivided into fixed-
size squares, and each square is filled with a graduated greyscale
extending from top left to bottom right.
LUT’s User LUT 1‘ to ‚User LUT 3‘ can be filled with user-specific function
values (see Function group ‚LUT programming‘“).
Example: w $10C $0601;User LUT 1 is selected
PROFILE_SW0SOURCE
PROFILE_SW1SOURCE
This register describes the source of switchport signal 0 or 1. A switchport
signal may be generated by the trigger module upon the event Trigger‘, ‚Start
of Integration‘ (SOI) or ‚End of Integration‘ (EOI), or due to a rising slope of
signal CC2 or CC3 (camera control 2/3) via the CameraLink interface.
Note: Events SOI and EOI will not occur in the rolling shutter mode as there is
no controlled integration time and, consequentially, no configured switchport
activities.
Example: w $10E #6 ;Switchport 0 upon event Reg.