Nortel Networks 207344-B Camcorder User Manual


 
Using the Centillion EtherSpeedII Switch Modules
4-4 207344-B
3. Verify that the port is transmitting and receiving data frames.
a. Check the green RJ-45 LED, which indicates a data exchange.
Refer to Appendix C,
LED Displays on the EtherSpeedII Switch
Modules, for additional information.
b. From the Map window in SpeedView, choose Statistics.
When the statistics information is displayed at the management station,
verify that the octet counts for transmit and receive are incrementing.
Also verify that the frame counts for transmit and receive unicast traffic
and for multicast traffic are incrementing.
c. From a configuration terminal connected to the serial port on the
switch, access the CLI.
Use the
show port command and specify the module number and port
number for the suspected port. Verify that the following counters are
incrementing:
InOctet
OutOctet
InUcastPkt
OutUcastPkt
MulticastTransmittedOk
MulticastReceivedOk
BroadcastTransmittedOk
BroadcastReceivedOk
4. If the port still fails, try inserting it into another switch network or
shared segment.
If the port functions correctly, check the status of the first switch network or
shared segment.
If the port fails to function, contact the nearest Nortel Networks Technical
Solutions Center. Be ready to give the service representative the information
listed on page 4-1
.