Panasonic AJ-HPX2000 Camcorder User Manual


 
180
Menu : Menu Description Tables
z The remaining battery level is indicated in percentage
when a battery with this function is installed on the unit.
The ____ in the Adjustable Range column indicates the
preset mode.
Items/
Data Saved
Adjustable
Range
Remarks
PAG L95
¢
Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL
:Set voltage manually.
11.0
:
13.5
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1
V steps.
–CUF–
BP-GL65/95
¢
Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.
AUTO
MANUAL
Select auto or manual to set the NEAR
END voltage.
AUTO: Set voltage automatically.
MANUAL
:Set voltage manually.
11.0
:
13.5
:
15.0
When MANUAL is selected in the menu
above, set the NEAR END voltage in 0.1
V steps.
–CUF–
BATTERY SETTING2
Items/
Data Saved
Adjustable
Range
Remarks
NiCd14
¢
Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.
NEAR END 11.0
:
13.8
:
15.0
Set the NEAR END voltage in 0.1 V
steps.
END 11.0
:
13.4
:
15.0
Set the END voltage in 0.1 V steps.
–CUF–
TYPE A
¢
Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.
FULL 12.0
:
15.1
:
17.0
Set the voltage to display the FULL
indication in 0.1 V steps.
NEAR END 11.0
:
13.6
:
15.0
Set the NEAR END voltage in 0.1 V
steps.
END 11.0
:
12.9
:
15.0
Set the END voltage in 0.1 V steps.
–CUF–
TYPE B
¢
Enable selection under BATTERY
SELECT.
¢:Enable selection.
: Disable selection.
FULL 12.0
:
15.5
:
17.0
Set the voltage to display the FULL
indication in 0.1 V steps.
NEAR END 11.0
:
13.5
:
15.0
Set the NEAR END voltage in 0.1 V
steps.
END 11.0
:
13.1
:
15.0
Set the END voltage in 0.1 V steps.
–CUF–
AJ-HPX2000P(VQT1D27-1)E.book 180 ページ 2007年7月30日 月曜日 午後1時31分