56
Adjustments and Settings for Recording
: Setting the Electronic Shutter
This section provides a description of the electronic shutter, together with setting and handling directions.
The table below lists the shutter modes in which the unit’s electronic shutter can be used as well as the shutter speeds which
can be selected.
For eliminating flicker due to lighting
For shooting fast moving subjects clearly
For shooting monitor screens in a way that minimizes the
pattern of horizontal lines
For shooting images when adding effects to the subjects’
movement
SYNCHRO SCAN:
Shutter is set using angle (deg) irrespective of
frame rate.
SYNCHRO SCAN2:
Shutter is set using time (sec) irrespective of
frame rate.
For shooting images when adding effects as if taken with
film
Notes
No matter in which mode the electronic shutter is used,
the higher the shutter speed, the lower the camera’s
sensitivity.
When the aperture is in the automatic mode, it will
increasingly open and the depth of focus will become
shallower as the shutter speed is increased.
By setting the shutter speed on the time axis (1/60, 1/100,
1/120, 1/250, 1/500, 1/1000, 1/2000), the frame rate can
be varied while keeping the exposure constant.
This is equivalent to Ramping (compensating for changes
in the frame rate using shutter angle) in a conventional film
camera.
* F displays the frame rate frequency for VFR. For example, if the VFR recording was done with a frame rate frequency of 15, the range of
the SYNCHRO SCAN will be from 1/15.
Setting the Electronic Shutter
Shutter Modes
To use the fixed shutter speed
To use the shutter speed of SYNCHRO SCAN
To use the half shutter speed (HALF)
Video system Fixed shutter speed
Half shutter
speed
Variable range for SYNCHRO
SCAN
Variable range for SYNCHRO
SCAN2
SYSTEM
MODE
CAMERA
MODE
Time/Angle display Time display Time display
Angle
display
Time display
Angle
display
1080-59.94i
60i
1/60, 1/100,
1/120, 1/250,
1/500, 1/1000,
1/2000, HALF
180.0 deg, 172.8 deg,
144.0 deg, 120.0 deg,
90.0 deg, 45.0 deg
Select from the
14 types above
1/120
1/61.7 - 1/7200
1/F* - 1/7200
3.0 -
350.0 deg
(In 0.5 deg
steps)
1/60.0 - 1/250
1/F* - 1/250
Angle not
displayed
30P 1/60
1/30.9 - 1/3600
1/F* - 1/3600
1/30.0 - 1/250
1/F* - 1/250
24P 1/48
1/24.7 - 1/2880
1/F* - 1/2880
1/24.0 - 1/250
1/F* - 1/250
24PA 1/48
1/24.7 - 1/2880
1/F* - 1/2880
1/24.0 - 1/250
1/F* - 1/250
1080-23.98PsF 24P 1/48
1/24.7 - 1/2880
1/F* - 1/2880
1/24.0 - 1/250
1/F* - 1/250
1080-24PsF 24P 1/48
1/24.7 - 1/2880
1/F* - 1/2880
1/24.0 - 1/250
1/F* - 1/250
1080-50i
50i
1/50, 1/60,
1/120, 1/250,
1/500, 1/1000,
1/2000, HALF
180.0 deg, 172.8 deg,
144.0 deg, 120.0 deg,
90.0 deg, 45.0 deg
Select from the
14 types above
1/100
1/51.4 - 1/6000
1/F* - 1/6000
1/50.2 - 1/250
1/F* - 1/250
25P 1/50
1/25.7 - 1/3000
1/F*- 1/3000
1/25.2 - 1/250
1/F* - 1/250
AJ-HPX3700G-VQT1V68_eng.book 56 ページ 2008年10月15日 水曜日 午後6時38分