[Image compression rate upon alarm detection]
Select “On” or “Off” to determine whether or not to change the image quality of “Quality1” (®page 47) upon
alarm detection.
• On: Images will be transmitted with the image quality selected for “Image quality upon alarm detection”.
• Off: Does not change the image quality upon alarm detection.
• Default: Off
[Image quality upon alarm detection]
Image quality can be changed upon an alarm occurrence. Select the image quality from the following.
0 Super fine/ 1 Fine/ 2/ 3/ 4/ 5 Normal/ 6/ 7/ 8/ 9 Low
• Default: 5 Normal
Note
• When privacy mode is active, black images will be transmitted.
11.4 Configure the settings relating to the alarm
output terminal [Alarm] (BL-VT164W/BL-VT164)
Click the [Alarm] tab on the “Alarm” page. (®page 34, page 35)
The settings relating to the alarm output terminal can be configured in this section.
Alarm output terminal setup
[Alarm output trigger]
Select “On” or “Off” to determine whether or not to output the alarm signals to the alarm output terminal when
an alarm is detected.
• Default: Off
[Alarm output type]
Select “Latch” or “Pulse” for the alarm output terminal at an alarm occurrence.
• Latch: When an alarm is detected, the alarm output terminal will be in the state selected for “Trigger
output” until the alarm occurrence indication button is clicked.
• Pulse: When an alarm is detected, the alarm output terminal will be in the state to the “Trigger output”
setting for the period set for “Pulse width”. When the alarm occurrence indication button is clicked, the
alarm output terminal will return to the normal state.
• Default: Latch
[Trigger output]
Select “Open” or “Close” to determine whether to open or close the alarm output terminal when outputting the
alarm signals.
• Open: The alarm output terminal will open when outputting the alarm signals. (Normally close)
82 Operating Instructions
11 Configure the alarm settings [Alarm]