Panasonic WV-NP472 Security Camera User Manual


 
-45-
SPECIFICATIONS
General
Ambient Operating Temperature: –10°C - +50°C (14°F - 122°F)
Ambient Operating Humidity: Less than 90 %
Power Source and Power Consumption: 12 V DC, 700 mA
Dimensions (without lens): 70 mm (W) x 65 mm (H) x 118 mm (D)
2-3/4” (W) x 2-5/8” (H) x 4-5/8” (D)
Weight (without lens): 0.51 kg (1.1 lbs.)
Network Section
Image Resolution: 640x480, 640x240, 320x240, 160x120 pixel
Image Process: JPEG (quality selectable Super Fine/ Fine/ Normal/ Rough)
Image Refreshing Rate: Fast/ Middle/ Slow/ Very Slow
Traffic Control: 32 kbps, 64 kbps, 128 kbps, 256 kbps, 512 kbps, 1 024 kbps, Unlimited
Protocol Supported: TCP/IP, HTTP, FTP, SMTP, DHCP, and DNS
OS Applicable: Windows 98 SE, Windows NT 4.0, Windows 2000, Windows ME, or
Windows XP
Browser Applicable: Internet Explorer 5.01 SP2, 5.5, 5.5 SP2, 6.0, or
Netscape Communicator 4.73, 4.78
Camera Section
Pick-up Device: 771 (H) x 492 (V) pixels, Interline Transfer CCD
Scanning Area: 4.8 (H) x 3.6 (V) mm (Equivalent to scanning area of 1/3” pick-up tube)
Scanning: 525 lines/60 fields/30 frames
Horizontal: 15.734 kHz
Vertical: 59.94 Hz
Synchronization: Internal, or Multiplexed Vertical Drive (VD2)
Video Output: 1.0 V[p-p] NTSC composite 75 /BNC connector
Horizontal Resolution: 480 lines (C/L), 570 lines (B/W)
Signal-to-Noise Ratio: 50 dB (Equivalent to AGC Off, Weight On)
Dynamic Range: 46 dB
Minimum Illumination: 0.8 lx (0.08 footcandle) at F1.4 (C/L), 0.1 lx (0.01 footcandle) at F1.4
(B/W)
Gain Control: ON (DNR-H), ON (DNR-L) or OFF (SET UP MENU) selectable
White Balance: ATW1, ATW2 or AWC (SET UP MENU) selectable
Aperture: Set Variable (SET UP MENU)
Sense Up: OFF, AUTO (x2, x4, x6, x10), FIX (x2, x4, x6, x10, x16, x32)
Super Dynamic2: ON or OFF (SET UP MENU) selectable
Electronic Light Control: 1/60 (OFF), 1/100, 1/250, 1/500, 1/1 000,1/2 000, 1/4 000, 1/10 000 s
selectable
Lens Mount: CS-mount (supplied with C-mount adapter)
ALC Lens: DC or Video selectable
Control Terminals: Alarm In: Pulled-up to 3.3V DC,
OFF (Open or 2 V DC – 12 V DC)/ ON (0 V 0.4 mA)
Alarm Out: Collector-output,
OFF (Open or 4 V DC – 5 V DC)/ ON (1 V 50 mA) Pulse/
Latch selectable
Auxiliary Out: Collector-output,
OFF (Open or 4 V DC – 5 V DC)/ ON (1 V 50 mA)
Day/Night In: Pulled-up to 5 V DC,
OFF (Open) / ON (0 V 0.2 mA)
Weights and dimensions indicated are approximate.