Samsung SCV-2082R Digital Camera User Manual


 
English_19
SETUP
EXPOSURE
EXPOSURE SETUP
1.
BRIGHTNESS
2.SHUTTER
4.SENS-UP
10
IIIIIIIII
*
IIIIIIII
3.AGC
HIGH
5.RETURN
AUTO
1.
When the SETUP menu screen is displayed, select EXPOSURE by using the Function
Setup switch so that the arrow indicates 'EXPOSURE'.
Select a desired mode using the Function
Setup switch.
2.
--- :
-
defOG
Through the defogging function, camera can automatically recognize fog concentration of the image, defog,
self correct in hazy, rainy, flue gas and other inclement weather to get a clear image.
1. When the SETUP menu screen is displayed, select ‘DEFOG’ by using the Function Setup switch.
2. Select a desired mode.
AUTO :
(low, middle, high).
OFF: Turn off Defogging function.
The camera will automatically correct image
according to the defogging level (low, middle,
high) set by the user.
Manual : The camera will adjust the definition of the
image according to user's preferences
through the defogging level
.
Defogging and SSDR function cannot be run simultaneously. When defogging function is set
to AUTO or MANUAL mode, SSDR function is not available. When SSDR functions is turned
on, defogging would become inactive
DEFOG SETUP
1.
LEVEL
MIDDLE
2.RETURN
MANUAL : You can control shutter speed manually.
-
You can select the shutter.
BRIGHTNESS : Adjusts the video brightness.
SHUTTER :
A.FLK :
-
Select this when you experience
picture fl icker, which can happen
when there is a clash with the
frequency of the installed lighting.
( NTSC MODEL : 1/60~1/120,000 , PAL MODEL : 1/50~1/120,000)
~
x4
AGC (AUTO GAIN CONTROL) (OFF/ LOW/ MIIDDLE/ HIGH) :
The higher gain level,
the brighter screen but the higher noise.
SENS-UP : When it is night or dark,the camera
automatically detects the light level and
maintains a clear picture if this model is
activated.
- OFF : Deactivates the SENS-UP function.
- AUTO : Activates the SENS-UP function.
RETURN Select this to save the changes in the EXPOSURE menu and return to the SETUP menu.
When the AGC is set to OFF, SENS-UP will be disabled.
LIMIT
AUTO
Press SET to Return
When the SENS-UP is set to OFF, the SHUTTER optional mode is A.FLK,MANUAL or ---.
Shutter speed is fixed.