16 Installing the Unit
1 Loosen the pan angle adjustment
screw.
The pan angle adjustment screw is
located on the angle adjuster bracket.
Loosen the screw with a Phillips
screwdriver before adjusting the camera
coverage.
2 Loosen the tilt angle adjustment
screw.
The tilt angle adjustment screw is
located on the side of the angle adjuster
bracket. Loosen the screw with a
Phillips screwdriver before adjusting the
lens position.
When you adjust the pan angle or tilt
angle without the loosening pan or tilt
angle adjustment screw, an internal
metallic part may be damaged.
3 Turn the lens in the desired direction.
You can adjust the lens position by
panning, tilting, or rotating.
4 When you have set the lens in the
desired direction, tighten the pan
angle adjustment screw and tilt angle
adjustment screw to lock in the lens
position.
5 Loosen the zoom lever and move it to
the right or left to adjust the angle of
view.
When you have set the zoom lever to the
desired position, tighten it to lock in the
angle of view.
6 Loosen the focus lever and move it to
the right or left to adjust the focal
length.
When you have set the zoom lever to the
desired position, tighten it to lock in the
focal length.
7 Repeat steps 1 to 6 until the camera
direction and coverage are
determined.
When adjusting the lens position, be
sure that the “MUP” mark on the angle
adjuster is toward the ceiling. If the
camera is installed with the “MUP”
mark toward the floor, the image
appears upside down.
If it is difficult to tighten the zoom
lever or focus lever, turn the lens a
little with the slip mechanism and try
again.
2 Adjusting the Camera
Direction and Coverage
Note
2, 4
1, 4
5
6
b
c
a
Notes