Sony DVW-790WS/790WSP Camcorder User Manual


 
7-32
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
3. On the setup menu, adjust as follows.
PAGE : S15*VF SETTING
ITEM : ZEBRA1 APT.LVL
(Factory setting: 10%)
Spec. :
Adjust for the desired width of detection.
4. On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : TEST SAW OFF
5. On the setup menu, set as follows.
PAGE : S15*VF SETTING
ITEM : ZEBRA SELECT 2
6. On the setup menu, adjust as follows.
PAGE : S15*VF SETTING
ITEM : ZEBRA2 DET. LVL
Spec. : Set the condition that zebra pattern
appears at the portion B.
Setting After Adjustment
. On the setup menu, set as follows.
PAGE : S15*VF SETTING
ITEM : ZEBRA SELECT 1
PAGE : S12*FUNCTION 1/2
ITEM : TEST OUT ENC
7-19. Zebra Adjustment
Preparation
. ZEBRA switch (viewfinder) ON
. On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : TEST OUT R, G or B
PAGE : S15*VF SETTING
ITEM : ZEBRA SELECT 1
ITEM : ZEBRA1 APT. LVL l%
. OUTPUT/DCC switch (inside panel) CAM/ON
. Shoot a grayscale chart in the full underscanned monitor
frame.
Equipment : Waveform monitor
Test point : TEST OUT connector
Setting point : 1 Lens IRIS
Spec. : A = 100 ±2 IRE (NTSC)
A = 700 ±14 mV (PAL)
Adjustment Procedure
Equipment : Black and white monitor
Test point : TEST OUT connector
1. On the setup menu, adjust as follows.
PAGE : S15*VF SETTING
ITEM : ZEBRA1 DET. LVL
Spec. : Set the condition that zebra pattern
appears at the portions A.
2. On the setup menu, set as follows.
PAGE : S12*FUNCTION 1/2
ITEM : TEST SAW ON
A
A
A
7-19. Zebra Adjustment
B