Sony DVW-790WS/790WSP Camcorder User Manual


 
4-13
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
Upper drum eccentricity adjustment tool
S reel table
Tension arm
Upper drum
2 nd groove from bottom
Probe
1 st groove from bottom
7. Upper Drum Eccentricity Adjustment
Tool Installation
(1) Clean the probes of the tool using a cleaning
cloth moistened with cleaning fluid.
m
. If the probes were dirty, the upper drum as-
sembly may scratch.
. If the probes were made of metal, it recom-
mends that lubricated protective tape puts on
the probes to prevent the scratching.
(2) Attach the tool as shown in the figure and ad-
just so that the probe is positioned between the
bottom two grooves of the five which locate
on the outside of the upper drum assembly.
n
Take care not to touch the probes against the
video heads
Probe
Tape (3 mm width)
Tape
4-2. Parts Replacement