Technicolor - Thomson CAMERA TTV 1707 Camcorder User Manual


 
Chapter 3 - Camera - DC/DC Converter 165
Camera Operation
THOMSON TTV1707 / CCU DT500
User manual
B1707M00LD
September 2000
MEM: Initial operation of the «RET» button displays the «RET1» or «RET2» video and
further operation of the button is required to return to the camera video display.
MON SELECT: Selection of video signal available on the «MONITOR» socket.
ENC: Encoded video
VF: viewfinder video (with character inlay).
NEUTRAL FILTER: Density wheel electrical control
Position 1: Clear
Position 2: T=25%
Position 3: T=6,3%
Position 4: T=1,6%.
PRGM MARKER 1: Programming of marker selected by «SELECT MARKER: 1»
(Refer to paragraph 2.2.3 - Marker functions).
PRGM MARKER 2: Programming of marker selected by «SELECT MARKER: 2»
(Refer to paragraph 2.2.3 - Marker functions).
SELECT MARKER: Marker selection.
0: No marker.
1: Displays markers programmed in «PRGM MARKER 1» (Refer to paragraph 2.2.3 -
Marker functions).
2: Display of markers programmed in «PRGM MARKER 2» (Refer to paragraph 2.2.3
Marker functions).
VF SELECT: Viewfinder video signal selection:
Y: Luminance signal
ENC: Encoded video
COL: Y, CR, CB (used with colour viewfinder)