VistaQuest N7227V5 Security Camera User Manual


 
– 37 –
To Either Temporarily Or Permanently Remove A Zone From The System (5800 System).
1. Enter the programming mode:
Key Installer Code + 8 + 0 and press [
][5][6].
2. Enter the zone number and press [
]. A summary display will appear.
3. Press [
] again.
20 Zone Type
Not Used 00
4. The “Zone Type” prompt will appear. Enter
[0][0]. This sets the zone type to “Not Used”.
Press [
] to continue.
20 Delete Zone?
1 = Yes 0 = No
5. The next prompt will ask whether you want to
delete the zone.
"Yes" will permanently remove the zone from
the system, while a "No" will disable it but retain
all data except the original zone type. You can then go back to this zone later
and put back an active zone type to re-enable it.
A serial number that has been entered for a 5800 system will not be
deleted if the zone is temporarily disabled by answering “No” to the
prompt above.
If only the physical transmitter is to be removed or changed (i.e., its serial
number deleted, as when replacing a unit that has a non-removable battery), it
can be done in
56 Mode, as indicated next.
Deleting a Transmitter Serial Number From a Zone in
56 Mode (5800 System)
The abbreviated procedure below can be used to delete a serial number from
a zone, using the
56 Mode.
1. In the programming mode, press [
][5][6] to enter Zone Programming
mode.
2. Then enter the zone number, and press [
] repeatedly until the cursor is
under the RF Input Loop (L) position. This is the specific input (loop) or
button on the transmitter that has been entered for that zone.
3. Enter a [0] at this point, then press [
].
4. A prompt "Delete S/N?" will appear.
Enter "Yes" to delete the existing serial number from the system.
Note that the other programmed values for that zone will not be deleted.
This will allow you to re-instate a new transmitter in its place.
5. A display for the next zone number will appear. To exit, enter “00".
6. Press
99 to exit the programming mode.
Check-Out Procedure for Wireless Zones
Transmitter ID
Sniffer Mode
(5700/5800
RF Systems)
When all transmitters have been installed, use the Transmitter Sniffer Mode to
test that they have all been properly programmed.
1. Enter Installer Code + # + 3. The keypad will display all zone numbers of
wireless units programmed into the system.
2. Fault each wireless zone, causing each device to transmit. As the system
receives a signal from each of the transmitters, the zone number of that
transmitter will disappear from the display.
If a 5700 transmitter is not dipswitched correctly, or if a 5800 transmitter is
not enrolled, its zone number will not turn off.
3. To exit the Transmitter Sniffer mode, enter the Installer Code + (OFF).
(Continued)