VistaQuest N7227V5 Security Camera User Manual


 
– 84 –
UL NOTICES
1. This is a "Grade A" residential system.
2. The 4285 Phone module and 7720PLUS or 7820 Long Range Radios have not been UL
tested and cannot, therefore, be used in a UL installation.
3. The Entry Delay (field
38) cannot be greater than 45 seconds for UL installations.
4. The maximum number of reports per armed period (field
92) must be unlimited (set to 1)
for UL installations.
5. Periodic testing (field
49) must be at least every 24 hours (set to 1) for UL installations.
6. Alarm Sounder plus Auxiliary Power currents must not exceed 600mA total for UL
installations.
7. Downloading is not permissible for UL installations.
CALIFORNIA STATE FIRE MARSHAL (CSFM) AND UL RESIDENTIAL FIRE
24 HOUR BATTERY BACK-UP REQUIREMENTS
The California State Fire Marshal and UL have regulations which require that all residential fire alarm control
panels must be provided with a back-up battery which has sufficient capacity to operate the panel and its
attached peripheral devices for 24 hours in the intended standby condition, followed by at least 4 minutes in
the intended fire alarm signaling condition.
This control panel can meet these requirements without using a supplementary power supply, provided that
the panel's auxiliary power and bell output currents are limited as indicated below.
OUTPUT LIMITATIONS TO MEET CSFM 24 HOUR BATTERY BACK-UP REQUIREMENTS
AND UL LISTED RESIDENTIAL FIRE INSTALLATIONS
OUTPUT CURRENT LIMITATIONS BATTERY INFORMATION
OUTPUT CURRENT
TOTAL
MAXIMUM
AUXILIARY CURRENT
BATTERY CAPACITY
TO USE (Amp/Hrs)
RECOMMENDED BATTERY
(Yuasa Model No.)
700mA maximum total
of
auxiliary power
plus bell output
currents.
45mA
160mA
200mA
425mA
500mA
4AH
7AH
8AH
14AH
17.2AH
NP4-12
NP7-12
NP4-12 (two)
NP7-12 (two)
NPG18-12
Note:
Use two batteries, connected in parallel. Obtain an Ademco Battery Harness kit. A dual battery harness is
provided with the kit. Both batteries will fit inside the panel's cabinet.