Axis Communications 225FD Digital Camera User Manual


 
44
AXIS 225FD - Troubleshooting
Emergency Recovery Procedure
If power to the AXIS 225FD is lost during the upgrade, the process will fail and the unit
will become unresponsive. A flashing red Status LED indicates a failed upgrade. To recover
the unit, follow the steps below. The serial number is found on the label attached to the
bottom of the camera.
1. Unix/Linux - From the command line, type the following:
arp -s <IP address of AXIS 225FD> <Serial number> temp
ping -s 408 <IP address of camera>
Windows - From a command/DOS prompt, type the following:
arp -s <IP address of AXIS 225FD> <Serial number>
ping -l 408 -t <IP address of camera>
2. If the unit does not reply within a few seconds, restart it and wait for a reply. Press
CTRL+C to stop Ping.
3. Open a browser and type in the camera’s IP address. In the page that appears, use the
Browse button to select the upgrade file to use, e.g. axis225fd.bin. Then click the Load
button to restart the upgrade process.
4. After the upgrade has completed (1-10 minutes), the unit will automatically restart and
show a steady green on the Power and Status LEDs and flashing green or amber on the
Network LED.
5. Reinstall the AXIS 225FD.
If the emergency recovery procedure does not get the camera up and running again, please
contact Axis support at www.axis.com/techsup/
Axis Support
If you contact Axis support, please help us to help you solve your problems, by providing
the server report, the log file and a brief description of the problem.
Server Report - go to Setup > System Options > Support Overview. The server report
contains important information about the server and its software, as well as a list of the
current parameters.
The Log file is available from Setup > System Options > Logs & Reports. The Log file
records events in the unit since the last system restart and can be a useful diagnostic tool
when troubleshooting.
Symptoms, Possible Causes and Remedial Actions
Hardware problems
Cannot close dome casing Check that the safety cord is not twisted or in the way of the camera optics.
Problems setting the IP address
When using ARP/Ping. Try the installation again. The IP address must be set within two minutes after running
the ARP command. Ensure the Ping length is set to 408.