Bosch Appliances GVS1000 Security Camera User Manual


 
20 en | Camera Default Configuration Global View Station 1000
F.01U.173.867 | 2.0 | 2010.11 Operations Manual Bosch Security Systems, Inc.
Mode 1
The table below shows the MODE 1 default camera settings for the camera.
Submenu Function Value
ALC ALC Level 0
Peak/Average 0
ALC Speed Medium
DVR/IP Encoder On
Shutter/AGC Shutter AES
Default Shutter 1/250
Gain Control AGC
Maximum AGC 15
SensUp 2x
Day/Night Day/Night Day
Switch Level 0
Priority Color
IR Contrast Normal
Color Burst On
Enhance/Dynamic Engine XF-Dynamic XF-DYN
Autoblack On
Black Level 0
Sharpness 10
DNR Auto
Peak White Invert OFF
Color White Balance ATW
Speed Medium
Red Gain 0
Blue Gain 0
Green Gain --
Saturation 5