Bosch Appliances VG5 600 Security Camera User Manual


 
AutoDome 600 Series Analog PTZ Camera On-Screen Display Menu Navigation | en 17
Bosch Security Systems, Inc. User Manual F.01U.270.005 | 2.0 | 2012.06
2.6 Communication Setup Menu
The Communication Setup Menu provides access to baud rate and Bilinx control settings.
Menu items marked with an asterisk (*) are the default settings.
Communication Setup Menu Choices:
Communication Setup
Exit...
* AutoBaud: ON
* Baud Rate 9600
* Bilinx: ON
Restore Defaults...
* = Factory Setting
Focus / Iris: Select
Menu Description Sub-menu / Description Default
Setting
Exit Saves and exits the menu.
AutoBaud Turns AutoBaud detection on. Toggles ON or OFF.
ON automatically accepts baud rates from 2400 to
57600.
(Note: If stepping from 2400 to 57600 baud, you
must first set the controller to 19200 for AutoBaud
to detect the higher baud rate.)
ON
Baud Rate Manually sets the baud rate when
AutoBaud is set to OFF.
Choices are 2400, 4800, 9600, 19200, 38400, and
57600. Then follow the OSD to confirm the
selection.
9600
Bilinx Turns on Bilinx control communication.
(Only available when not connected to
a Bilinx data interface unit.)
Toggles ON or OFF.ON