Bosch Appliances VG5 600 Security Camera User Manual


 
AutoDome 600 Series Analog PTZ Camera Pelco On-Screen Menus | en 39
Bosch Security Systems, Inc. User Manual F.01U.270.005 | 2.0 | 2012.06
PTZ Setup Menu Choices:
5.1.4 Other Menus
Menu Description Sub-menu / Description Default
Setting
Exit Exits the menu.?
Edit Tour 1 Accesses the Add /
Remove Scenes On
Standard Tour 1 Menu.
Exit: Exits the menu.
Scene (1 - 5): Adds or removes
scenes from the Standard Tour.
Edit Tour 2 Accesses the Edit Custom
Tour Menu.
Exit: Exits the menu.
Scene (1 - 5): Adds or removes
scenes from the Custom Tour.
Tour 1 Period Changes the length of
waiting time between
presets.
Sliding scale: – (3 sec. to 10 min.) + 5 sec.
Tour 2 Period Changes the length of
waiting time between
presets.
Sliding scale: – (3 sec. to 10 min.) + 5 sec.
Scan Speed Changes the Autopan and
AutoScan speeds.
Sliding scale: – (1°/sec to 60°/sec)
+
30°/
sec.
Edit Presets Modifies preset scenes. 1-99 scenes
Limit Stops Toggles the Limit Stops for
AutoScan.
ON or OFF OFF
Recordings Selects record Pattern 1 or
2, if normal pattern
command does not
respond.
A” or “B “A”
AutoPivot Follows a subject while
beneath the camera,
without inverting the
picture.
ON or OFF ON
Menu Description Default
Setting
Edit Password Sets or displays the password. See Section 1.4 Setting
Passwords, page 8.
FastAddress (locked) Sets or changes the AutoDome address. Not Set
Software Version
(unlocked)
Displays the camera software version.
Ack and Reset Alarms Acknowledges and resets alarms. If there is no active
alarm input, the OSD displays the following message:
No Active Alarms.
Restore All Settings
(locked)
Restores all settings to their original factory default
settings.
Reset All Memory
(locked)
Restores all settings to their original factory default
settings and clears all user programmed settings such
as preset scenes and recordings.