7.8.2 Displaying Azimuth, Elevation, and Compass Headings
You can display only the azimuth/elevation readings or only the compass reading, or you can
display both readings at the same time. The AutoDome displays the azimuth/elevation
readings and the compass heading in the following way:
180 / –45 S
where:
180 is the Azimuth or the pan location in degrees.
–45 is the Elevation or the tilt location in degrees.
S is the compass direction (cardinal or intercardinal).
1. Press ON-95-ENTER to display the azimuth/elevation reading.
2. Press ON-96-ENTER to display the compass heading.
3. Press OFF-95-ENTER to hide the azimuth/elevation reading.
4. Press OFF-96-ENTER to hide the compass heading.
7.9 AutoHome Recalibration Commands and Settings
The AutoHoming routine may be enabled for any site that is experiencing a large amount of
shifts in masks, prepositions, or playback tours. This feature adds the following AUX
commands to configure and to enable the AutoHome Recalibration feature:
Function
Key
Command
Number
Command Description
On/Off 680 Homing Recalibration
Display
Displays the current mode of operation,
intervals, time until the next calibration, and
the number of recalibrations that have
occurred.
On – Turns display on.
Off – Turns off the display.
On/Off 681 Homing Recalibration On – Enables recalibration (This action does
not cause the dome to re-home immediately)
Off – Disables recalibration
On 682 Recalibration Mode Each On command toggles the recalibration
mode as follows:
Recalibrates only on the loss of home
position.
Recalibrates on the loss of home and for
every periodic interval.
On/Off 683 Recalibration Interval Changes the homing recalibration interval.
Intervals are in 6-hour increments up to 72
hours.
Each On – increases interval by 6 hours
Each Off – decreases interval by 6 hours
On/Off 684 Initial Offset Time Sets the initial offset time for the recalibration
interval. The offset time starts after the Homing
Calibration is enabled. The recalibration
interval begins its countdown after the offset
time.
Each On – increases offset time by 4 hours
Each Off – decreases offset time by 4 hours
Note: The offset time does not take effect until