Canon 2812B015 Security Camera User Manual


 
5-12
List of Log Messages
A272 Upload communication buffer overflowed [warning]
A321 Video control command failed [err]
A420 Video input initialization failed [crit]
A421 Video control command failed [crit]
A422 Video input frozen [crit]
A423 Video input error detected [crit]
Description ftp/http queue is full (A272)
Meaning Upload data overflowed from the communication buffer.
Countermeasure
Make adjustments to reduce the number of event occurrences. Also adjust
the upload quality, image size and frame rate.
Description video%1 command error - <Cause of error> (A321)
%1 Video input number
Meaning
Issuance of a command to the video input system failed. If this error
occurs frequently, an A42x error will occur.
Description video%1 initialization failure - <Cause of error> (A420)
%1 Video input number
Meaning
The video input function was stopped because the video input system
could not be initialized.
Description video%1 command error - <Cause of error> (A421)
%1 Video input number
Meaning
The video input function was stopped because issuance of an essential
command to the video input system failed.
Description video%1 stalled (A422)
%1 Video input number
Meaning The video input function was stopped because video generation stopped.
Description video%1 fatal error - <Error code> (A423)
%1 Video input number
Meaning
The video input function was stopped because an error that does not
permit recovery of the video input system was detected.