D.1.1.6 Dynamic threshold
f The change was made to the bytes in the set window parameter as follows:
- Byte 3E
f M3096G: Xπ00π: Default; Simplified DTC, if IPC option is selected.
Xπ01π to XπFFπ Reserved
f M3097G: DTC SELECTION BYTE
Reserved
b7 b6 b5 b4 b3 b2 b1 b0
Example: Xπ00π is ™Default; Simplified DTC, if IPC II option is selected∫.
DTC SELECTION
0 0: Default; Simplified DTC, if IPC II optioned.
0 1: Dynamic threshold
1 0: Simplified DTC, if IPC II optioned.
1 1: Reserved
Byte 3E
Reserved
- Byte 2F
f M3096G: Reserved
f M3097G: The definitions of the byte are the same as those of M3097G
control register #3. For further details, refer to OEM
Manual 50FH5037E.
Restrictions:This byte is effective only when byte 3E is Xπ40π.
- Byte 30
f M3096G: Reserved
f M3097G: The definitions of the byte are the same as those of M3097E
control register #4. For further details, refer to OEM
Manual 50FH5037E.
Restrictions:This byte is effective only when byte 3E is Xπ40π.
f How to specify the parameter
- When Simplified DTC is used:
Specified as ™Byte 17 (threshold)=Xπ00π, Byte 3E (DTC
SELECTION)=Xπ00π or Xπ80π.
- When Dynamic threshold is used:
Specify as ™Byte 17=Xπ00π, Byte 3E=Xπ40π, Byte 2F/30∫.
D $ 9